Spanish
No tienes artículos en tu carrito de compras.

Smart Bag PA EE-300, EE - Standard sleeve (top) + M6 connector (side), 300 L

Sku: 3008-97880
Marca: GL Sciences
$873.00
+ -

Especificaciones

Smart Bag PA EE-300, EE - Standard sleeve (top) + M6 connector (side), 300 L SKU: 3008-97880

Especificaciones
Nombre del atributoValor de atributo
ConexiónEE - Standard sleeve (top) + M6 connector (side)
Volumen300 L
MaterialPolyvinyl alcohol film
Espesor53 µm
Temperatura máxima120 °C
Unidades / Pk1 pc.
SolicitudIn-cabin VOC’s, Vehicle emission, Emitted gases from materials, Permanent gases

Smart Bag PA - Overview

Blank Test​

 

Each sampling bag (1L) was filled with nitrogen and put in an oven at 60 °C. 1 hour later, the each gas in the bags is withdrawn into a gas tight micro syringe and injected directly to a GC/MS. Both bags were not flushed/cleaned with nitrogen.

 

Smart Bag PA

Time (min.)

Tedlar Bag

Time (min.)

 
 

Aldehydes/Acetone Blank Test 

 

After being filled with nitrogen, both bags were closed and put in an oven at 60 °C. 1 hour later, each 1L gas in the bags was vacuumed with a pump through a DNPH cartridge and eluted sample was analyzed by HPLC. The both bags were not flushed/cleaned before the test.

 
 
 

Storage Stability of Organic Solvent Gases in Smart Bag PA and Tedlar Bag 

 

The same volume with the same constitution of vaporized standards were introduced to each bag. Then nitrogen was added to each bag and were measured by a GC/FID. 

Standard Compound List: Acetone, Methylethylketone, Methyl isobutyl ketone, Isopropyl alcohol, Isobutyl alcohol, 1-Butanol, Ethylbenzene, Cyclohexane, n-Hexane,o-Xylene, m-Xylene Toluene, Dichloromethane, Methyl acetate, Ethyl acetate, Isobutyl acetate, n-Butyl acetate (50 ng/mL each)

 

Storage Stability of Malodorous Compounds in Smart Bag PA and Tedlar Bag 

 

After preparation of each malodorous sample as described below, 5L Smart Bag PA and 5 L Tedlar Bag were filled with the sample together with nitrogen gas. Concentration changes over time were calculated with a detecting tube at certain times.

 
 

Gas Permeability Test

 

Permeation rates of O 2 , N 2 , CH 4 and CO 2 were measured using a permeation rate measurement system on each sampling bag.

 

Documentos

Solicitar Información / Cotización

*
*
*
Smart Bag PA EE-300, EE - Standard sleeve (top) + M6 connector (side), 300 L