Spanish
No tienes artículos en tu carrito de compras.
 
 
 

Thermo Fisher Scientific GC column equivalent - Trace, TraceGOLD, TracePLOT, & More

InertCap logo
Thermo Fisher equivalent GC column - InertCap picture

GL Sciences equivalent for Thermo Fisher Scientific GC Columns

InertCap GC columns from GL Sciences are an excellent alternative to Thermo Fisher Scientific GC columns with a wide selection of compatible siloxane phases featuring high-inertness and ultra-low bleed. Get better resolution for gas chromatography.

 
Thermo Fisher equivalent GC column - InertCap picture
 
High inertness

High Inertness

GL Sciences᾽ proprietary inert processing technology completely eliminates residues of metal, halide, and silanol which are in the column's inner surface. It is possible to obtain excellent symmetry peaks for polar, basic, acidic compounds and metal ligands.

Ultra low bleed

Ultra Low Bleed

Based on superior technologies for cross-linking of stationary phases and surface deactivation of fused silica, InertCap GC columns for GC/MS analysis offers technologies with ultra-low bleed.

Quality

Quality

InertCap Capillary GC columns are manufactured and shipped under strict quality control at the GL Science factory, Japan, in accordance with ISO9001 quality certification. InertCap is tested by standard samples which include high adsorption compounds.

For more information, visit InertCap

 
 

Recommended GL Sciences equivalent for Thermo Fisher Scientific Trace TR-5

InertCap 5

100% dimethypolysiloxane

Low polarity 5% diphenyl – 95% dimethylpolysiloxane column. InertCap 5 is an optimal first choice column for a variety of general analyses such as pesticides and volatile compounds etc.

  • Fused silica
  • 5% diphenyl - 95% dimethylpolysiloxane
  • USP G27
  • Low polarity
  • Cross-linked
  • Fused silica
  • 5% diphenyl - 95% dimethylpolysiloxane
  • USP G27
  • Low polarity
  • Cross-linked
 
100% dimethypolysiloxane
 

Recommended GL Sciences equivalent for Thermo Fisher Scientific Trace TR-1MS

InertCap 1MS

5% diphenyl, 95% dimethylpolysiloxane

Non-polar column bonded with 100% dimethylpolysiloxane. Samples elute in order of low boiling points. Designed for GC/MS, InertCap 1MS delivers high inertness and ultra low bleed.

  • Fused silica
  • 100% dimethylpolysiloxane
  • USP G2
  • Non-polar
  • Cross-linked
  • Fused silica
  • 100% dimethylpolysiloxane
  • USP G2
  • Non-polar
  • Cross-linked
 
5% diphenyl, 95% dimethylpolysiloxane
 

Recommended GL Sciences equivalent for Thermo Fisher Scientific Trace TR-1701

InertCap 1701

14% cyanopropylphenyl, 86% dimethylpolysiloxane

Medium polarity column bonded with 14% cyanopropylphenyl and 86% dimethylpolysiloxane. InertCap 1701 is suitable for pesticides screening analyses.

  • Fused silica
  • 14% cyanopropylphenyl - 86% dimethylpolysiloxane
  • USP G46
  • Medium polarity
  • Cross-linked
  • Fused silica
  • 14% cyanopropylphenyl - 86% dimethylpolysiloxane
  • USP G46
  • Medium polarity
  • Cross-linked
 
14% cyanopropylphenyl, 86% dimethylpolysiloxane
 
 

Complete list of InertCap equivalent phases for Thermo Fisher Scientific GC columns

 

Macherey-Nagel

Phase

USP Code

InertCap
TR-1MS100% DimethylpolysiloxaneG1, G2, G38InertCap 1MS
TR-1100% DimethylpolysiloxaneG1, G2, G38InertCap 1
TR-5MS5% Diphenyl (equiv.) - Dimethylpolysilphenylene siloxaneG27, G36InertCap 5MS/Sil
TR-55 % Diphenyl - 95 % DimethylpolysiloxaneG27, G36InertCap 5MS/NP
TR-55 % Diphenyl - 95 % DimethylpolysiloxaneG27, G36InertCap 5
TR-35MS35% Diphenyl(equiv.) - 65% DimethylpolysiloxaneG42InertCap 35MS
TR-35MS35% Diphenyl - 65% DimethylpolysiloxaneG42InertCap 35
TR-170114% Cyanopropylphenyl - 86% DimethylpolysiloxaneG46InertCap 1701MS
TR-170114% Cyanopropylphenyl - 86% DimethylpolysiloxaneG46InertCap 1701
TR-50MS50 % Diphenyl(equiv.) - 50 % Dimethylsilphenylene SiloxaneG3InertCap 17MS/Sil
TR-50MS50% Diphenyl - 50% DimethylpolysiloxaneG3InertCap 17MS
TR-WAXPolyethylene Glycol(PEG)G14, G15, G16,
G20, G39, G47
InertCap Pure-WAX
TR-WAXPolyethylene Glycol(PEG)G14, G15, G16,
G20, G39, G47
InertCap WAX
TR-WAXPolyethylene Glycol(PEG)G14, G15, G16,
G20, G39, G47
InertCap WAX-HT
 
 
Application Search
 

Find The Right Column For Your Compound

Thousands of applications notes available. Search by compound, category, phase and more.  

 
;;