Agilent GC column equivalent - J&W, CP-Sil, Varian, Chrompak & More

Agilent equivalent GC column - InertCap logo
Agilent equivalent GC column - InertCap picture

GL Sciences equivalent for Agilent GC Columns

InertCap GC columns from GL Sciences are an excellent alternative to Agilent GC columns with a wide selection of compatible siloxane phases featuring high-inertness and ultra-low bleed. Get better resolution for gas chromatography.

 
Agilent equivalent GC column - InertCap picture
 
High inertness

High Inertness

GL Sciences᾽ proprietary inert processing technology completely eliminates residues of metal, halide, and silanol which are in the column's inner surface. It is possible to obtain excellent symmetry peaks for polar, basic, acidic compounds and metal ligands.

Ultra low bleed

Ultra Low Bleed

Based on superior technologies for cross-linking of stationary phases and surface deactivation of fused silica, InertCap GC columns for GC/MS analysis offers technologies with ultra-low bleed.

Quality

Quality

InertCap Capillary GC columns are manufactured and shipped under strict quality control at the GL Science factory, Japan, in accordance with ISO9001 quality certification. InertCap is tested by standard samples which include high adsorption compounds.

For more information, visit InertCap

 
 

Recommended GL Sciences equivalent for Agilent J&W DB-5, HP-5, ULTRA-2, CP Sil 8 CB

InertCap 5

100% dimethypolysiloxane

Low polarity 5% diphenyl – 95% dimethylpolysiloxane column. InertCap 5 is an optimal first choice column for a variety of general analyses such as pesticides and volatile compounds etc.

  • Fused silica
  • 5% diphenyl - 95% dimethylpolysiloxane
  • USP G27
  • Low polarity
  • Cross-linked
  • Fused silica
  • 5% diphenyl - 95% dimethylpolysiloxane
  • USP G27
  • Low polarity
  • Cross-linked
 
100% dimethypolysiloxane
 

Recommended GL Sciences equivalent for Agilent J&W DB-1ms UI, HP-1ms UI, VF-1ms, CP-Sil 5 CB Low Bleed/MS

InertCap 1MS

5% diphenyl, 95% dimethylpolysiloxane

Non-polar column bonded with 100% dimethylpolysiloxane. Samples elute in order of low boiling points. Designed for GC/MS, InertCap 1MS delivers high inertness and ultra low bleed.

  • Fused silica
  • 100% dimethylpolysiloxane
  • USP G2
  • Non-polar
  • Cross-linked
  • Fused silica
  • 100% dimethylpolysiloxane
  • USP G2
  • Non-polar
  • Cross-linked
 
5% diphenyl, 95% dimethylpolysiloxane
 

Recommended GL Sciences equivalent for Agilent J&W DB-1ms UI, HP-1ms UI, VF-1ms, CP-Sil 5 CB Low Bleed/MS

InertCap 1701

14% cyanopropylphenyl, 86% dimethylpolysiloxane

Medium polarity column bonded with 14% cyanopropylphenyl and 86% dimethylpolysiloxane. InertCap 1701 is suitable for pesticides screening analyses.

  • Fused silica
  • 14% cyanopropylphenyl - 86% dimethylpolysiloxane
  • USP G46
  • Medium polarity
  • Cross-linked
  • Fused silica
  • 14% cyanopropylphenyl - 86% dimethylpolysiloxane
  • USP G46
  • Medium polarity
  • Cross-linked
 
14% cyanopropylphenyl, 86% dimethylpolysiloxane
 
 

Complete list of InertCap equivalent phases for Agilent GC columns

 

Agilent

Phase

USP Code

InertCap
DB-1ms UI, HP-1ms UI, VF-1ms, CP-Sil 5 CB Low Bleed/MS100% DimethylpolysiloxaneG1, G2, G38InertCap 1MS
DB-1, HP-1, ULTRA-1, CP-Sil 5 CB100% DimethylpolysiloxaneG1, G2, G38InertCap 1
DB-5ms, DB-5ms UI, VF-5ms5% Diphenyl (equiv.) - Dimethylpolysilphenylene siloxaneG27, G36
HP-5ms, HP-5ms UI, CP Sil 8 CB Low Bleed/MS5 % Diphenyl - 95 % DimethylpolysiloxaneG27, G36
DB-5, HP-5, ULTRA-2, CP Sil 8 CB5 % Diphenyl - 95 % DimethylpolysiloxaneG27, G36InertCap 5
DB-624 UI, VF-624ms, CP-Select 624 CB6 % Cyanopropylphenyl - 94 % DimethylpolysiloxaneG43InertCap 624MS
DB-624, VF-624ms, CP-Select 624 CB6 % Cyanopropylphenyl - 94 % DimethylpolysiloxaneG43InertCap 624
HP-1301, VF-1301ms, CP-13016% Cyanopropylphenyl - 94% DimethylpolysiloxaneG43InertCap 1301
DB-35ms, DB-35ms UI, VF-35ms35% Diphenyl(equiv.) - 65% DimethylpolysiloxaneG42InertCap 35MS
HP-35, DB-35, VF-35ms35% Diphenyl - 65% DimethylpolysiloxaneG42InertCap 35
DB-1701, VF-1701ms, CP-Sil 19 CB14% Cyanopropylphenyl - 86% DimethylpolysiloxaneG46
DB-1701, VF-1701ms, CP-Sil 19 CB14% Cyanopropylphenyl - 86% DimethylpolysiloxaneG46InertCap 1701
HP-17, DB-17ms, VF-17ms, CP-Sil 24 CB Low Bleed/MS50 % Diphenyl(equiv.) - 50 % Dimethylsilphenylene SiloxaneG3
InertCap 17MS/Sil
HP-17, DB-17ms, VF-17ms, CP-Sil 24 CB Low Bleed/MS50% Diphenyl - 50% DimethylpolysiloxaneG3InertCap 17MS
DB-17, HP-50, CP-Sil 24 CB50% Diphenyl - 50% DimethylpolysiloxaneG3InertCap 17
DB-210, DB-200, VF-200ms50 % Trifluoropropyl - 50 % DimethylpolysiloxaneG6InertCap 210
DB-225, CP Sil 43 CB50 % Cyanopropylmethyl - 50 % PhenylmethylpolysiloxaneG7, G19InertCap 225
HP-INNOWAX, CP Wax 52 CBPolyethylene Glycol(PEG)G14, G15, G16,
G20, G39, G47
DB-WAX, CP Wax 52 CBPolyethylene Glycol(PEG)G14, G15, G16,
G20, G39, G47
InertCap WAX
DB-WAXetr, VF-WAXms, CP Wax 52 CBPolyethylene Glycol(PEG)G14, G15, G16,
G20, G39, G47
DB-FFAP, HP-FFAP, CP WAX 58 CBNitroterephthalic acid modified Polyethylene GlycolG35InertCap FFAP
CP-VolamineUnique-
 
 